The Measurable difference.

TRION3 – Highspeed DAQ

TRION3 - Highspeed Signal Conditioning Modules

Are you looking for a future-proof signal conditioning technology which offers the flexibility for tomorrow without any drawbacks? Then the TRION3 highspeed series is the ideal solution for you. These signal conditioning modules find use when precision, speed and dynamics are essential.

Overview of DEWETRON's TRION3 modules

In the following table, you find an overview of DEWETRON’s highspeed TRION3 modules. For more information, please refer to our technical reference manual or get in contact with us.

MODULE CHANNELS SAMPLE RATE PER CHANNEL RESOLUTION ISOLATION CONNECTOR TYPES
TRION3-1820-MULTI-AOUT-8 IN: 8
OUT: 8
2 MS/s 24-bit IN: Yes
OUT: Yes
IN: LEMO OB
OUT: D-SUB, BNC
TRION3–AOUT-8 OUT: 8 2.5 MS/s Up to 32-bit Yes OUT: D-SUB, BNC
TRION3-1850-MULTI 4 or 8 5 MS/s 24-bit (>2 MS/s: 18-bit) Yes 4 D-SUB or 8 LEMO OB
TRION3-1820-MULTI 4 or 8 2 MS/s 24-bit (>2 MS/s: 18-bit) Yes 4 D-SUB or 8 LEMO OB
TRION3-1810M-POWER-4 8 (4 U, 4 I) 10 MS/s 18-bit Yes Safety banana, D-SUB

The highspeed DEWE3 systems support both, TRION as well as TRION3 modules. The preceding DEWE2 series only supports TRION modules.

Examples for compatible sensors

Isolated highspeed inputs

The TRION(3)-18xx-MULTI modules are faster than any other similar module on the market. Some of the keyfacts are:

  • Simultaneous sample rate of up to 5 MS/s
  • Analog bandwidth of 2 MHz
  • Continuous data streaming to application and disk
  • Channel to channel, channel to ground, both isolated (350 V)
  • For DEWE2 (2 MS/s) and DEWE3 (5 MS/s)

Onboard filtering and signal processing

To provide excellent signal to noise ratio and aliasing free data, we equipped the module with:

  • Analog anti-aliasing filter
  • Precise lowpass filter with Bessel and Butterworth characteristic up to 8th order with freely programmable cutoff frequency
  • AC-coupling programmable (0.16 Hz to 100 Hz)
  • Linearization of RTD and thermocouple sensors

ultra-low noise and distortion

Analog circuit design and AD-conversion at a glance. Better performance than any other 24-bit highspeed measurement system.

  • Outstanding dynamic range (140 dB)
  • Highest accuracy also for AC
  • Market leading number of effective bits
  • Best solution for analysis of dynamic signals in mechanical structure analysis
  • THD -108 dB at 1 kHz

Powerful excitation

Voltage and current controlled sensor excitation for almost every sensor type. There is enough power to supply sensors with high demand as well:

  • 0 to 24 V with up to 100 mA (max. 0.5 W)
  • 0.1 to 60 mA with up to 24 V (>20 mA: 10 V)
  • Highest accuracy of 0.02%
  • No power sharing between individual inputs

More about the multi-purpose modules

INPUT TYPES RANGES SUPPORTED SENSORS
Voltage
±2 mV to ±100 V freely programmable
IEPE®
100 mV to ±10 V freely programmable IEPE® sensors
Bridge
1 to 1000 mV/V 4-, 5-, 6-wire full bridge; 3-, 4-, 5-wire ½ bridge;
2-, 3-, 4-wire ¼ bridge; 120 / 350 / 1000 Ω
Resistance
10 Ω to 30 kΩ Potentiometer, resistance temperature detection:
Pt100, Pt200, Pt300, Pt500, Pt2000 (2-, 3-, 4-wire)
Current
±30 mA 4 to 20 mA sensors;
loop powered sensors
CAN
CAN 2.0
MSI
MSI-BR-CH-x: 500 to 50000 pC
MSI-BR-TH-x: various TC ranges
MSI-BR-LVDT
LVDT, RVDT, charge output and thermocouple sensors
Voltage input accuracy ≤10 V DC
0.1 Hz to 10 kHz
10 kHz to 50 kHz
50 kHz to 100 kHz
±0.02 % of reading, ±0.02 % of range ±20 μV
±0.02 % of reading, ± 0.02 % of range ±20 μV
±0.1 % of reading, ± 0.02 % of range ±20 μV
±0.5 % of reading, ± 0.02 % of range ±20 μV
Input impedance Differential (100 MΩ or 1 MΩ), Single ended (50 MΩ)
Input coupling DC / AC (highpass filter 0.16 Hz to 100 Hz freely programmable)
Spurious free SNR (10 V range) 1 kS/s to 200 kS/s: 140 dB

10+ measurement modes for almost every sensor and application:

  • 9 native modes: bridge, voltage, current, IEPE, resistance, potentiometer, temperature (RTD), counter and CAN
  • MSI compatibility for charge, thermocouple and LVDT input

The most user friendly data acquisition software OXYGEN will lead you to very quick and reliable measurement results.

Back to top
Contact us Contact us

Do you have a question?

Kontakt-Formular