The Measurable difference.

DEWE-800

Flexible data acquisition system for laboratory use DEWE-800

KEY FACTS

  • 5 PCI slots for ORION A/D boards
  • 16 slots for DAQP/HSI modules
  • AC or DC powered
  • 70 MB/s stream-to-disk rate
DEWE-800

CONNECTIVITY

SOFTWARE

The DEWE-800 can use its full potential with the OXYGEN measurement software.

Screens of DEWETRON's measurement software OXYGEN

HSI MODULES SELECTION GUIDE

Choose from different HSI modules which are single channel, analog high-speed isolation amplifiers  with an analog ±5 V output. They provide a bandwidth up to 2 MHz.

High-speed isolation amplifiers up to 2 MHz bandwidth
Name Channels Bandwidth Sensor supply Voltage range [V] Current IEPE Bridge Charge Thermocouple Resistance, RTD Others
HSI-STG-D 1 ISO 2 MHz 0-12 V 0-20 mA ±10 V TEDS
HSI-HV 1 ISO 2 MHz ± 1400 V CAT III 600V
HSI-LV (2-pin types) 1 ISO 2 MHz ±50 V
HSI-LV (multi-pin types) 1 ISO 2 MHz ±50 V
HSI-LV-B PM-CM-60 1 ISO 800 kHz 60A DC, Peak
HSI-LV-B PM-CM-200 1 ISO 500 kHz 200A DC, Peak
HSI-LV-B PM-CM-400 1 ISO 500 kHz 400A DC, Peak
HSI-LV-B PM-CM-700 1 ISO 250 kHz 700A DC, Peak
HSI-LV-B PM-CM-1000 1 ISO 500 kHz 1000 ADC, Peak

DAQP MODULES SELECTION GUIDE

Choose from different DAQP modules which are single channel, dynamic isolation amplifiers with bandwidth up to 300 kHz, an analog ±5 V output and RS-485 interface.

DAQP isolation amplifiers
Name Channels Bandwidth Sensor supply Voltage range [V] Current IEPE Bridge Charge Thermocouple Resistance, RTD Others
DAQP-MULTI 1 ISO 3 kHz 1-4 mA ±5 V TEDS
DAQP-STG 1 ISO 300 kHz 0-12 V, 0-20 mA ±10 V TEDS
DAQP-STG-S6 1 ISO 300 kHz 0-12 V, 0-20 mA ±10 V TEDS
DAQP-HV 1 ISO 300 kHz ± 1400 V CAT III 600V
DAQP-LV (2-pin types) 1 ISO 300 kHz ±50 V
DAQP-LV (multi-pin types) 1 ISO 300 kHz ±50 V
DAQP-LV-D PNA-CLAMP-150-DC 1 ISO 100 kHz 150 A_DC 500 A_DC (for 1 min)
DAQP-LV-D PNA-CLAMP-1800-DC 1 ISO 20 kHz 1800 A_DC
DAQP-LA-B 1 ISO 300 kHz ± 5A (±30Apeak )
DAQP-LA-B-S1 1 ISO 300 kHz ± 0.6A
DAQP-CFB2 1 TEDS
DAQP-CHARGE-A 1 50 kHz 4mA
DAQP-CHARGE-B 1 ISO 100 kHz
DAQP-THERM 1 ISO 3 kHz TEDS
DAQP-FREQ-A 1 ISO 200 kHz ±9 V, 12 V Frequency

STATIC PAD MODULES

PAD amplifiers
Name Channels Sampling [kS/s] / [bit] Sensor supply Voltage range [V] Current IEPE Bridge Thermocouple Charge Resistance, RTD Others
PAD-TH8 8 ISO +12 V ± 50 V RS-485 OUT
PAD-V8 8 ISO +12 V ±50 RS-485 OUT
PAD-DO7 7 OUT RS-485 IN, 7 Relais

CPAD/EPAD MODULES

Different external, multichannel CPAD and EPAD modules can be connected and combine analog signal conditioning and A/D converter in an extreme rugged box
Name Channels Sampling [kS/s] / [bit] Interface Voltage range [V] Current Thermocouple Resistance, RTD Others
CPAD3-V8 8 ISO 100 / 20 CAN 2.0B ± 50
CPAD3-TH8 8 ISO 100 / 20 CAN 2.0B
CPAD2-V8 8 ISO 12 / 24 CAN 2.0B ± 50
CPAD2-TH8 8 ISO 12 / 24 CAN 2.0B
CPAD2-RTD8 8 ISO 12 / 24 CAN 2.0B
CPAD2-LA8 8 ISO 12 / 24 CAN 2.0B
EPAD2-V8 8 ISO 12 / 24 RS-485 ± 50
EPAD2-TH8 8 ISO 12 / 24 RS-485
EPAD2-RTD8 8 ISO 12 / 24 RS-485
EPAD2-LA8 8 ISO 12 / 24 RS-485

A/D BOARDS

Name Resolution Sampling/ch [max.] Digital inputs Digital I/O Counter/Encoder CAN
DEWE-ORION-0816-10Mx 16 bit 10 MS/s 8 2 (32 bit synchronous) up to 2
DEWE-ORION-0816-5Mx 16 bit 5 MS/s 8 2 (32 bit synchronous) up to 2
M2I.4931 16 bit 30 MS/s
M2I.4932 16 bit 30 MS/s
M2I.4963 16 bit 30 MS/s on 4 channels, 60 MS/s on 2 channels
M2I.4964 16 bit 30 MS/s on 8 channels, 60 MS/s on 4 channels
Back to top
Contact
us

Do you have a question?

Kontakt-Formular