DEWE-510

KEY FACTS

  • 3 PCI slots for ORION A/D boards
  • 16 slots for DAQP/HSI modules
  • AC, DC or battery powered
  • 70 MB/s stream-to-disk rate

Data sheet download

DEWE-510 flexible data recorder

CONNECTIVITY

  • SYNC-CLOCK™ synchronizes all signal sources:
    • DAQP/HSI modules
    • Video cameras
    • FlexRay interface
    • GPS
  • Expandable with
    • DEWE Front-end chassis
      (for more DAQP/HSI slots)
    • CPAD/EPAD (for slow inputs)

SOFTWARE

  • DEWETRON’s turnkey software OXYGEN
  • Also available with 3rd party software, e.g. NI LabVIEW, Vector CANape
  • Optional comprehensive project framework

HSI MODULES UP TO 2 MHZ

HSI Modules
Name Channels Bandwidth Sensor supply Voltage range [V] Current IEPE Bridge Inductive bridge Thermocouple Charge Resistance, RTD Others
HSI-STG-D 1 ISO 2 MHz 0-12 V 0-20 mA ±10 V TEDS
HSI-HV 1 ISO 2 MHz ± 1400 V CAT III 600V
HSI-LV (2-pin types) 1 ISO 2 MHz ±50 V
HSI-LV (multi-pin types) 1 ISO 2 MHz ±50 V
HSI-LV-B PM-CM-60 1 ISO 800 kHz 60A DC, Peak
HSI-LV-B PM-CM-200 1 ISO 500 kHz 200A DC, Peak
HSI-LV-B PM-CM-400 1 ISO 500 kHz 400A DC, Peak
HSI-LV-B PM-CM-700 1 ISO 250 kHz 700A DC, Peak
HSI-LV-B PM-CM-1000 1 ISO 500 kHz 1000 ADC, Peak

DAQP MODULES UP TO 300 KHZ

Name Channels Bandwidth Sensor supply Voltage range [V] Current IEPE Bridge Inductive bridge Thermocouple Charge Resistance, RTD Others
DAQP-MULTI 1 ISO 3 kHz 1-4 mA ±5 V TEDS
DAQP-STG 1 ISO 300 kHz 0-12 V, 0-20 mA ±10 V TEDS
DAQP-STG-S6 1 ISO 300 kHz 0-12 V, 0-20 mA ±10 V TEDS
DAQP-HV 1 ISO 300 kHz ± 1400 V CAT III 600V
DAQP-LV (2-pin types) 1 ISO 300 kHz ±50 V
DAQP-LV (multi-pin types) 1 ISO 300 kHz ±50 V
DAQP-LV-D PNA-CLAMP-150-DC 1 ISO 100 kHz 150 A_DC 500 A_DC (for 1 min)
DAQP-LV-D PNA-CLAMP-1800-DC 1 ISO 20 kHz 1800 A_DC
DAQP-LA-B 1 ISO 300 kHz ± 5A (±30Apeak )
DAQP-LA-B-S1 1 ISO 300 kHz ± 0.6A
DAQP-CFB2 1 TEDS
DAQP-CHARGE-A 1 50 kHz 4mA
DAQP-CHARGE-B 1 ISO 100 kHz
DAQP-THERM 1 ISO 3 kHz TEDS
DAQP-FREQ-A 1 ISO 200 kHz ±9 V, 12 V Frequency
DAQP-ACC-A 1 4/8 mA 4/8 mA

STATIC PAD MODULES

pad-modules

Name Channels Sampling [kS/s] / [bit] Sensor supply Voltage range [V] Current IEPE Bridge Thermocouple Charge Resistance, RTD Others
PAD-TH8 8 ISO +12 V ± 50 V RS-485 OUT
PAD-V8 8 ISO +12 V ±50 RS-485 OUT
PAD-DO7 7 OUT RS-485 IN, 7 Relais

CPAD/EPAD MODULES

Name Channels Sampling [kS/s] / [bit] Interface Voltage range [V] Current Thermocouple Resistance, RTD Others
CPAD3-V8 8 ISO 100 / 20 CAN 2.0B ± 50
CPAD3-TH8 8 ISO 100 / 20 CAN 2.0B
CPAD2-V8 8 ISO 12 / 24 CAN 2.0B ± 50
CPAD2-TH8 8 ISO 12 / 24 CAN 2.0B
CPAD2-RTD8 8 ISO 12 / 24 CAN 2.0B
CPAD2-LA8 8 ISO 12 / 24 CAN 2.0B
EPAD2-V8 8 ISO 12 / 24 RS-485 ± 50
EPAD2-TH8 8 ISO 12 / 24 RS-485
EPAD2-RTD8 8 ISO 12 / 24 RS-485
EPAD2-LA8 8 ISO 12 / 24 RS-485

A/D BOARDS

Name Analog input Resolution Sampling/ch [max.] Digital inputs Digital I/O Counter/Encoder CAN
DEWE-ORION-0816-10Mx 16 bit 10 MS/s 8 2 (32 bit synchronous) up to 2
DEWE-ORION-0816-5Mx 16 bit 5 MS/s 8 2 (32 bit synchronous) up to 2
M2I.4931 4 channels (single ended), 2 channels (differential) 16 bit 30 MS/s
M2I.4932 8 channels (single ended), 4 channels (differential) 16 bit 30 MS/s
M2I.4963 4 channels (single ended), 2 channels (differential) 16 bit 30 MS/s on 4 channels, 60 MS/s on 2 channels
M2I.4964 8 channels (single ended), 4 channels (differential) 16 bit 30 MS/s on 8 channels, 60 MS/s on 4 channels
Back to top
Contact
us

Do you have a question?